Amprobe TMD-51 Thermometer K/J-Type with Memory

  • Highly accurate thermometer with 0.1% basic accuracy for precise measurements
  • Dual input T1, T2, T1-T2
  • Large, backlit easy to read display
  • In-field thermocouple offset adjustment
  • °C/°F selection
  • Robust protective Holster
  • Auto-Power Off
  • MIN/MAX/HOLD functions
Category:

Description

The Amprobe TMD-51 thermometer is a professional choice for HVAC/R technicians, electricians, research, industrial process, and quality control. The dual inputs allow easy super-heat and sub-cool temperature measurement as well as cut-out and in temperature measurements.

Specifications

FEATURE TMD-50 TMD-51 TMD-52 TMD-53 TMD-53W TMD-55 TMD-56 TMD-55W
Thermocouple type K K, J K, J, T, E K, J K, J K, J, T, E, R, S, N
Basic accuracy 0.1 % 0.1 % 0.05 % 0.05 % 0.05 % 0.05 % 0.05 % 0.05 %
Number of parameters on the display 1 1 3 3 3 3 3 3
Real time clock – wireless beeper with setting
Wireless transmission
Data capture 125 Samples 128 Samples 256 Samples 128 Samples
Data logger 1024 Points 16000 Points 1024 Points
PC interface Wireless USB Wireless
Thermocouple Type Temperature Range
K-TYPE -328 °F → 2501 °F (-200 °C → 1372 °C)
J-TYPE -346 °F → 2192 °F (-210 °C → 1200 °C)
T-TYPE -328 °F → 752 °F (-200 °C → 400 °C)
E-TYPE -346 °F → 1832 °F (-210 °C → 1000 °C)
R-TYPE 32 °F → 3212 °F (0 °C → 1767 °C)
S-TYPE 32 °F → 3212 °F (0 °C → 1767 °C)
N-TYPE -58 °F → 2372 °F (-50 °C → 1300 °C)

 

What’s Included

  • TMD-51
  • 2-type k thermocouple
  • Batteries (installed)

Resources

Datasheet »
Product Manual »

1 review for Amprobe TMD-51 Thermometer K/J-Type with Memory

  1. NVNDAVE

    This Thermometer works well, has some bugs.

    The Thermometer works well, however it has some bugs in the software. A couple of times when using it there was a lockup where it would not measure or turn off. The only way to get out of this is to remove the batteries and then reinstall them. The unit is accurate and responds well to changes in Ambient Temperature. It works well for measuring Sub-Cooling and Super-Heat. The two thermocouples must be insulated from each other or it generates error. The Fieldpiece ST-4 does not have this problem.

    ✔ Yes, I recommend this product.